Jan 30, 2012 58,461 mi

CRACKS ON THE HIGH PRESSURE SIDE OF FUEL PUMP AT THE FITTING. THIS WILL CAUSE FUEL TO LEAK UNDER OPERATION WITH POSSIBLE FIRE. PUMP DESIGN IS FAULTY AND A RECALL SHOULD BE INTIATED FOR THIS DANGEROUS PROBLEM. *TT

Jan 30, 2012 58,461 mi

CRACKS ON THE HIGH PRESSURE SIDE OF FUEL PUMP AT THE FITTING. THIS WILL CAUSE FUEL TO LEAK UNDER OPERATION WITH POSSIBLE FIRE. PUMP DESIGN IS FAULTY AND A RECALL SHOULD BE INTIATED FOR THIS DANGEROUS PROBLEM. *TT

Jan 29, 2012 66,051 mi

CRACKS HAVE DEVELOPED IN THE FUEL QUICK DISCONNECT REINFORCEMENT FLANGE ON THE FUEL PUMP HOUSING. THIS COULD LEAD TO A FUEL LEAK (AND HAS IN MANY CASES) ON TO THE EXHAUST PIPE, IGNITION SYSTEM COMPONENTS, AND MY LEFT LEG. *TT

Jan 29, 2012 66,051 mi

CRACKS HAVE DEVELOPED IN THE FUEL QUICK DISCONNECT REINFORCEMENT FLANGE ON THE FUEL PUMP HOUSING. THIS COULD LEAD TO A FUEL LEAK (AND HAS IN MANY CASES) ON TO THE EXHAUST PIPE, IGNITION SYSTEM COMPONENTS, AND MY LEFT LEG. *TT

Jan 23, 2012 24,000 mi

MULTIPLE CRACKS IN FUEL PUMP HOUSING AT FLANGE WHERE FUEL LINE CONNECTS. ODOR AND GAS LEAKAGE. *TR

Jan 23, 2012 24,000 mi

MULTIPLE CRACKS IN FUEL PUMP HOUSING AT FLANGE WHERE FUEL LINE CONNECTS. ODOR AND GAS LEAKAGE. *TR

Nov 15, 2011 75,076 mi

FUEL WAS LEAKING FROM THE FLANGE AROUND THE FEMALE QUICK-DISCONNECT FITTING. PLASTIC FLANGE IS LOCATED ON TOP OF FUEL TANK. REPLACED PLASTIC FITTING WITH METAL ONE BUT LEAKS CONTINUED. PLACED ORIGINAL FITTING BACK AND USED A FUEL-RESISTANT SEALING COMPOUND TO STOP LEAKS. HAVE NOT EXPERIENCED ANY LARGE LEAKS RECENTLY BUT AM CONCERNED THIS PATCH WILL START LEAKING AGAIN. IT WAS A FRIGHTENING EXPERIENCE TO BE RIDING AND SEEING GAS SPLATTER ON YOUR CLOTHES - COULDN'T WAIT UNTIL I GOT HOME. THE FLANGE DESIGN IS AT FAULT BECAUSE IT PREVENTS A SOLID CONNECTION OF HIGH PRESSURE GASOLINE LINES TO THE FUEL TANK. *TR

Nov 15, 2011 75,076 mi

FUEL WAS LEAKING FROM THE FLANGE AROUND THE FEMALE QUICK-DISCONNECT FITTING. PLASTIC FLANGE IS LOCATED ON TOP OF FUEL TANK. REPLACED PLASTIC FITTING WITH METAL ONE BUT LEAKS CONTINUED. PLACED ORIGINAL FITTING BACK AND USED A FUEL-RESISTANT SEALING COMPOUND TO STOP LEAKS. HAVE NOT EXPERIENCED ANY LARGE LEAKS RECENTLY BUT AM CONCERNED THIS PATCH WILL START LEAKING AGAIN. IT WAS A FRIGHTENING EXPERIENCE TO BE RIDING AND SEEING GAS SPLATTER ON YOUR CLOTHES - COULDN'T WAIT UNTIL I GOT HOME. THE FLANGE DESIGN IS AT FAULT BECAUSE IT PREVENTS A SOLID CONNECTION OF HIGH PRESSURE GASOLINE LINES TO THE FUEL TANK. *TR

Aug 28, 2008 11,750 mi

TL*THE CONTACT OWNS A 2005 BMW R1200 RT. WHILE THE VEHICLE WAS STOPPED, THE CONTACT SMELLED GAS. HE NOTICED GASOLINE DRIPPING FROM THE TAIL PIPE AND HIS PANTS. THE CONTACT REPLACED THE FUEL CHECK VALVE COVER HIMSELF. THE DEALER STATED THAT THE FUEL VALVE COVER FAILING DUE TO THE DEFECTIVE PLASTIC WAS A COMMON ISSUE. THE CURRENT AND FAILURE MILEAGES WERE 11,750.

Aug 28, 2008 11,750 mi

TL*THE CONTACT OWNS A 2005 BMW R1200 RT. WHILE THE VEHICLE WAS STOPPED, THE CONTACT SMELLED GAS. HE NOTICED GASOLINE DRIPPING FROM THE TAIL PIPE AND HIS PANTS. THE CONTACT REPLACED THE FUEL CHECK VALVE COVER HIMSELF. THE DEALER STATED THAT THE FUEL VALVE COVER FAILING DUE TO THE DEFECTIVE PLASTIC WAS A COMMON ISSUE. THE CURRENT AND FAILURE MILEAGES WERE 11,750.