1993 CHEVROLET S10 Fuel System, Gasoline Problems

20 complaints about Fuel System, Gasoline

20
Complaints
0
Crashes
3
Fires
0
Deaths

High Severity Issue

This component has been associated with crashes, fires, or deaths.

This Problem Across All Years

All Fuel System, Gasoline Complaints (20)

Dec 24, 2003 Fire

VEHICLE EXPERIENCED MOTOR TROUBLE THEN CAUGHT ON FIRE.*MR *PH WHILE DRIVING THE VEHICLE BEGAN TO EXPERIENCE ENGINE PROBLEM. THE CONSUMER PULLED OVER ONTO THE SHOULDER TO ATTEMPT REPAIRS WHEN THE VEHICLE CAUGHT ON FIRE. THE FIRE CAUSED DAMAGE TO THE HOOD AND ENGINE COMPARTMENT. *NM

Nov 5, 2003

THE FUEL WIRING HARNESS ON THE FUEL PUMP MELTED. *JB DEFECT WAS NOTICED WHILE REPLACING THE FUEL TANK. REPLACED FUEL TANK, SENDING UNIT AND PUMP. *PH

Mileage: 170,000

Aug 25, 2003

FUEL PUMP POWER WIRE AND CONNECTOR BURNED/CHARRED AT UPPER CONNECTOR INSIDE GAS TANK. *AK

Mileage: 160,000

Jun 23, 2003

CENTRAL MULTIPORT FUEL INJECTOR ASSEMBLY FAILED, CAUSING FUEL TO ENTER THE OIL PAN AND DAMAGE THE MOTOR. FUEL WAS SPRAYING UNDER THE PHLENEM AND COULD HAVE CAUSED A FIRE. SAME UNIT HAS FAILED JUST OVER 15 MONTHS LATER, AGAIN SPRAYING GAS UNDER THE PHLENEM, THANKFULLY AGAIN NO FIRE,JUST SPRAYING OF GAS. *NLM

Mileage: 131,300

Sep 5, 2001

CONSUMER RECEIVED INFORMATION IN WRITING FROM TECHNICIAN AND GARAGE ABOUT FUEL PUMP WHICH COULD FAIL DUE TO WIRING SHORTING OUT. CONSUMER WAS CONCERNED ABOUT A FIRE.*AK

Jun 4, 2001

PLASTIC COVER ON FUEL TANK GATHERED AND RETAINED WATER ON TOP OF FUEL TANK ALLOWING TANK TO RUST REQUIRING TANK, FULE PICK, PUMP AND STRANER REPLACEMENT.*AK

Feb 15, 2001

ORIGINAL INTAKE MANIFOLD GASKET FAILURE LEADING TO COOLANT ENTERING LUBRICATION SYSTEM. AFTER GASKET WAS REPLACED DAMAGE OCCURRED TO ENGINE BEARING, RODS AND POSSIBLY CAMSHAFT. REQUIRED ENGINE REPLACEMENT.*AK

Feb 12, 2001

CONSUMER HAD TAKEN VEHICLE TO REPAIR SHOP AND TECHNICIAN FOUND A PROBLEM WITH CENTRAL FUEL INJECTION, WHERE THE FUEL WAS GETTING MIXED WITH OIL, AND CAUSING VEHICLE TO LOSE POWER WHEN ACCELERATING OR SLOWING DOWN. *AK

Jan 19, 2000

DEFECTIVE FUEL INJECTOR ASSEMBLY CAUSED ENGINE PROBLEMS. YH

Nov 12, 1999

THE PLASTIC STONE SHIELD ALLOWED WATER TO REMAIN IN CONTACT WITH THE FRONT LOWER EDGE OF THE FUEL TANK. THIS CAUSED THE TANK TO RUST THROUGH AND LEAK. THE PLASTIC SHIELD CONTAINED THE LEAK, CONCENTRATING THE LEAKED FUEL BEFORE SPILLING IT OUT ONTO THE GROUND. THIS WAS AN ORIGINAL TANK, THE TRUCK HAS NEVER BEEN OFF-ROAD, NOR IN AN ACCIDNET. THE POOR DESIGN OF THE SHILED/TANK ASSEMBLY ALLOWED TRAPPED WATER TO CAUSE A POTENTIALLY DANGEROUS CONDITION TO EXIST. *AK

Sep 2, 1999

AFTER SMELLING A STRONG FUEL ODOR AND COLLECTING A CERTAIN AMOUNT OF FUEL LEAKING FROM THE TRUCK, THE DEALER WAS NOTIFIED. OWNER HAD TRUCK TOWED TO DEALERSHIP WHERE THE FUEL TANK WAS FOUND TO BE CORRODED. PLEASE PROVIDE ANY FURTHER INFORMATION. *AK

Nov 17, 1998

FUEL PUMP FAILED TO OPERATE. LEARNED OF A TECHNICAL BULLETIN CONTAINING INFORMATION ON DEFECTIVE FUEL PUMP. INFORMED DEALER WHO REFUSED TO REPAIR BECAUSE VEHICLE WAS OUT OF WARRANTY. *AK

Aug 28, 1998

THE COVER UNDERNEATH THE GAS TANK HAS MORE THAN AN INCH OF SPACE WHICH CAUSES ROCKS AND PEBBLES TO GET INTO THE GAS, RESULTING IN A GAS LEAK, MAY CAUSE A FIRE. PLEASE PROVDIE DETAILS. *AK

Mar 5, 1998

APPARENTLY SAND WAS TRAPPED AROUND THE AREA OF THE TANK SHIELD FROM DRIVING ON OFF ROAD CONDITION, REUSULTING IN RUSTING OUT THE TANK.

Mar 24, 1997

DUE TO CORROSION DISTRIBUTOR FAILED, CAUSING THE VEHICLE NOT TO ACCELERATE OVER 50.

Oct 29, 1996

FUEL TANK LEAK.

Jun 13, 1996

FUEL TANK/PUMP REPLACED DUE TO RUSTED TANK.

Jun 13, 1996

FUEL TANK/PUMP REPLACED DUE TO RUSTED TANK.

Oct 25, 1995 Fire

CONSUMER SON WAS DRIVING THE TRUCK START TO SMOKE TRUCK WAS TOTALED , RECEIVED A RECALL LETTER ON THIS PROBLEM CAN'T FIND THIS RECALL . TT

Feb 16, 1995 Fire

VEHICLE CAUGHT ON FIRE WITH FLASH AND CAB FILLING WITH SMOKE AFTER BEING PARKED FOR ABOUT 5 MINTUES. TT