10
Complaints
0
Crashes
0
Fires
0
Deaths

This Problem Across All Years

All Fuel System, Gasoline Complaints

Showing 10 of 10
Sep 29, 2011

THE CURRENT RECALL DIDN'T GO BACK FAR ENOUGH, SINCE MY F150 GAS STRAPS ALSO BROKE OFF. *TT

Sep 29, 2011

THE CURRENT RECALL DIDN'T GO BACK FAR ENOUGH, SINCE MY F150 GAS STRAPS ALSO BROKE OFF. *TT

Feb 7, 2005 110,080 mi

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE. *JB

Feb 7, 2005 110,080 mi

A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE. *JB

Jan 15, 2004 184,000 mi

I HAVE A DUAL FUEL TANK SYSTEM. THE REAR TANK IS PUMPING GAS INTO THE FORWARD TANK. THE FORWARD TANK IS OVERFLOWING PAST THE FILLER CAP AND SPILLING TO THE GROUND. THESE SYMPTOMS ARE INDENTICAL TO THE 1993 F-SERIES FUEL SYSTEMS PROBLEMS NHTSA ID # 00V-424, MFG CAMPAIGN # 00S57. I JUST WENT TO THE LOCAL FORD DEALER. THEY LOOKED UP MY VIN AND SAID THAT MY VEHICLE IS NOT LISTED UNDER THIS RECALL. THE DEALER IS MORE THAN WILLING TO HELP. I WAS TOLD THAT THE SERVICE TECHNICIAN WOULD FIRST HAVE TO TROUBLESHOOT THE CAUSE AND FIND OUT IF THE FAILURE IS DUE TO THE SAME PART BEING DEFECTIVE AS THE RECALL ITEMS. THEN I WOULD HAVE TO BATTLE FORD TO PAY FOR THE FIX. I WAS TOLD THAT THEY SOMETIMES HAVE TROUBLE GETTING FORD TO PAY FOR REPAIRS IF THE VEHICLE IS NOT LISTED ON THE RECALL, EVEN IF IT IS THE SAME PART MALFUNCTIONING. I AM GOING TO BEGIN REPAIRING THE VEHICLE SOON AND WOULD APPRECIATE ANY HELP YOU CAN GIVE ME. HAVING SEEN THAT THESE SAME SYMPTOMS HAVE APPEARED ON EARLIER MODELS I HAVE COME TO THE CONCLUSION THAT THIS IS NOT AN ISOLATED INCIDENT AND SUSPECT THAT OTHER SAME YEAR VEHICLES AS MY MAY DEVELOP THIS PROBLEM.

Jan 15, 2004 184,000 mi

I HAVE A DUAL FUEL TANK SYSTEM. THE REAR TANK IS PUMPING GAS INTO THE FORWARD TANK. THE FORWARD TANK IS OVERFLOWING PAST THE FILLER CAP AND SPILLING TO THE GROUND. THESE SYMPTOMS ARE INDENTICAL TO THE 1993 F-SERIES FUEL SYSTEMS PROBLEMS NHTSA ID # 00V-424, MFG CAMPAIGN # 00S57. I JUST WENT TO THE LOCAL FORD DEALER. THEY LOOKED UP MY VIN AND SAID THAT MY VEHICLE IS NOT LISTED UNDER THIS RECALL. THE DEALER IS MORE THAN WILLING TO HELP. I WAS TOLD THAT THE SERVICE TECHNICIAN WOULD FIRST HAVE TO TROUBLESHOOT THE CAUSE AND FIND OUT IF THE FAILURE IS DUE TO THE SAME PART BEING DEFECTIVE AS THE RECALL ITEMS. THEN I WOULD HAVE TO BATTLE FORD TO PAY FOR THE FIX. I WAS TOLD THAT THEY SOMETIMES HAVE TROUBLE GETTING FORD TO PAY FOR REPAIRS IF THE VEHICLE IS NOT LISTED ON THE RECALL, EVEN IF IT IS THE SAME PART MALFUNCTIONING. I AM GOING TO BEGIN REPAIRING THE VEHICLE SOON AND WOULD APPRECIATE ANY HELP YOU CAN GIVE ME. HAVING SEEN THAT THESE SAME SYMPTOMS HAVE APPEARED ON EARLIER MODELS I HAVE COME TO THE CONCLUSION THAT THIS IS NOT AN ISOLATED INCIDENT AND SUSPECT THAT OTHER SAME YEAR VEHICLES AS MY MAY DEVELOP THIS PROBLEM.

Apr 15, 2003 200,440 mi

FORD-F150 WITH 2 FUEL TANKS. REAR FUEL TANK LEAKS GAS FROM BOTTOM OF TANK ABOVE SPARE TIRE. THIS TRUCK IS ONLY 8 YEARS OLD AND IS ALWAYS IN USE/TANKS ARE ALWAYS ROTATED.*JB

Apr 15, 2003 200,440 mi

FORD-F150 WITH 2 FUEL TANKS. REAR FUEL TANK LEAKS GAS FROM BOTTOM OF TANK ABOVE SPARE TIRE. THIS TRUCK IS ONLY 8 YEARS OLD AND IS ALWAYS IN USE/TANKS ARE ALWAYS ROTATED.*JB

Jun 7, 2000

TRUCK HAS DUAL FUEL TANKS. FUEL TANK WOULD LEAK. ALSO, WHILE PERFORMING AN OIL CHANGE NOTICED THAT ENGINE OIL PAN HAD CORRODED. *AK

Jun 7, 2000

TRUCK HAS DUAL FUEL TANKS. FUEL TANK WOULD LEAK. ALSO, WHILE PERFORMING AN OIL CHANGE NOTICED THAT ENGINE OIL PAN HAD CORRODED. *AK