Recall 13V378000
ELECTRICAL SYSTEM
Defect Description
Altec is recalling certain model year 2005-2013 AH75/85/100 aerial devices manufactured April 2005 through April 2013; and equipped with current leakage monitoring systems. The cable for the current leakage monitoring system may be too long and may breach the gap provided by the lower boom fiberglass insert chassis insulating system.
Safety Consequence
If the gap is breached, then the boom may conduct electrical current, increasing the risk of electrical shock to the operator.
Remedy
Altec will notify owners and dealers will inspect and properly secure the leakage monitor cable. The recall is expected to begin during September 2013. Altec's recall number is CSN 585. Owners may contact Altec at 1-877-462-5832.
Affected Vehicles
| Year | Make | Model |
|---|---|---|
| 2005 | ALTEC | AH100 |
| 2005 | ALTEC | AH75 |
| 2005 | ALTEC | AH85 |
| 2006 | ALTEC | AH100 |
| 2006 | ALTEC | AH75 |
| 2006 | ALTEC | AH85 |
| 2007 | ALTEC | AH100 |
| 2007 | ALTEC | AH75 |
| 2007 | ALTEC | AH85 |
| 2008 | ALTEC | AH100 |
| 2008 | ALTEC | AH75 |
| 2008 | ALTEC | AH85 |
| 2009 | ALTEC | AH100 |
| 2009 | ALTEC | AH75 |
| 2009 | ALTEC | AH85 |
| 2010 | ALTEC | AH100 |
| 2010 | ALTEC | AH75 |
| 2010 | ALTEC | AH85 |
| 2011 | ALTEC | AH100 |
| 2011 | ALTEC | AH75 |
| 2011 | ALTEC | AH85 |
| 2012 | ALTEC | AH100 |
| 2012 | ALTEC | AH75 |
| 2012 | ALTEC | AH85 |
| 2013 | ALTEC | AH100 |
| 2013 | ALTEC | AH75 |
| 2013 | ALTEC | AH85 |
Check your vehicle: Visit NHTSA.gov and enter your VIN to see if your specific vehicle is affected.